Selection Criteria for Buck Converters

FAQ

Selection Criteria for Buck Converters

Fundamentals of Buck Converters

Buck converter is a switch-mode step-down converter that offers high efficiency and flexibility at high step-down ratios (VIN/VOUT ) and at high load currents. Its basic circuit is shown in Figure 1. Inside most Buck converters there is a high-side MOSFET plus a low-side synchronous rectifier MOSFET switched by an internal duty-cycle control circuit, to regulate the average output voltage. The switching-node waveform is filtered by an external LC filter; the output voltage is sensed via a feedback loop and the high-side duty cycle is controlled, giving voltage regulation. Non-synchronous devices have no internal low-side MOSFET and only connect a Schottky diode from the external switching node to ground.

Technical Document Image Preview

Figure 1. Basic circuit of a Buck converter

The MOSFETs operate in alternating on/off mode, so power loss is very low; and by controlling their duty cycle, high step-down ratios (VIN/VOUT). The on-resistance of the internal MOSFETs (RDS(ON) ) determines the Buck converter's load capability, while the MOSFET voltage rating determines its maximum input voltage.



Selection of Voltage and Current Absolute Maximum Ratings


Application Input Voltage

When selecting a suitable Buck converter, the first parameter to consider is the input voltage range. Richtek's Buck converters fall mainly into three categories:

  • LV Buck converter: input voltage (VIN) range of 2.5V to 5.5V
  • 8V HV Buck converter: input voltage (VIN) range of 4.5V to 18V
  • HV Buck converter: input voltage (VIN) range of 4.5V to 36V.

LV Buck converters suit single-cell lithium-ion battery applications best, but can also be used in 5V supply applications.

Technical Document Image Preview

Figure 2. Richtek step-down converter selection flow

18V HV Buck converters are common in 12V supply applications, but their wide voltage range also allows use in 5V supply applications.

Devices from 21V / 23V / 24V to 36V have a very broad application range. They are usually chosen when the input voltage tolerance is large, or when a Buck converter must handle a fluctuating input. 36V devices are typically used in 24V DC industrial supplies, or automotive applications where the supply fluctuates widely, such as a 13.5V car battery.


Application Current Consumption

When considering the rated load current, both the average and the maximum current consumed in the application must be taken into account.

The average current must be lower than the converter's rated load current; the difference depends on the converter's power dissipation and the thermal conditions in the application. This average current sets the heat loss of the switching MOSFETs, including conduction and switching loss. Conduction loss relates to the internal on-resistance (RDS(ON) ): namely I2* RDS(ON). If the RDS(ON) of high and low side differ, the power dissipation of both MOSFETs must also be considered when considering the step-down ratio. Switching loss relates to current, input voltage and switching frequency. In typical applications it is about 30% of total loss; in high input voltage or high frequency applications it rises substantially. Total power loss can be calculated from the datasheet efficiency curves: Note that this power loss also includes inductor loss, about 10%~20% of the total. The maximum power dissipation allowed by the IC depends on the package, PCB layout and maximum ambient temperature. Widening the copper traces to the IC pins and package thermal pad during PCB design increases the ability to dissipate power.

Technical Document Image Preview

Figure 3. Efficiency curves at different output voltages

The maximum current should usually equal the converter's rated load current and may sometimes be slightly higher. When designing, ensure the maximum load current does not trigger the converter's over-current protection (OCP). Buck converters sense the inductor peak current (valley current in ACOT devices), and the datasheet OCP value refers to this peak or valley. The difference between load current and inductor peak or valley current is half the inductor ripple current, so the ripple also affects how the maximum application load current relates to the OCP value.

Technical Document Image Preview

Figure 4. Over-current protection of a Buck converter

 



Light-Load Efficiency (PSM Type or Forced PWM Type)

For supplies used in low-power standby modes, step-down converter light-load efficiency should be as high as possible. In forced-PWM step-down converters the switching frequency is fixed over the full load range; that is, with a high frequency at light load, most of the loss comes from switching loss.

For supplies used in low-power standby modes, Buck converter light-load efficiency should be as high as possible. In a forced-PWM Buck converter the switching frequency is constant over the full load range, so if a high frequency is used at light load most of the loss is switching loss. Buck converters that raise light-load efficiency lower the frequency at light load and are usually called pulse-skipping mode (PSM**). The principle: as the load falls, the inductor current valley reaches zero at some point; in a forced-PWM device the low-side MOSFET keeps conducting, so the inductor current even goes negative. In a PSM device the low-side MOSFET is turned off, leaving the switching node floating until the next high-side turn-on. The high-side minimum on-time sets the peak inductor current, and average current can only be lowered by reducing the switching frequency, i.e. by adjusting the internal frequency to skip pulses. PSM regulation mainly compares the valley of the output ripple with an internal reference. At light load PSM can drop the frequency to a few kHz, cutting switching loss and greatly raising light-load efficiency.

PSM mode has some disadvantages:

  • The output ripple voltage is a low-frequency triangular wave that is hard to filter. Depending on the PSM scheme and component values its amplitude may be higher than in PWM mode; some loads may not tolerate it.
  • When a PSM converter suddenly meets a step load it switches quickly from PSM to PWM mode; compared with a forced-PWM converter this gives a larger output voltage undershoot.
  • The average voltage in PSM mode is usually slightly higher than in PWM mode (~1%).
  • Because the frequency is variable, PSM mode can sometimes interfere with adjacent sensitive circuits.

If the application does not need better light-load efficiency, choose a forced-PWM device, since it operates more stably at all loads.

*In some Richtek documents the forced-PWM type is called PWM mode, or continuous conduction mode, etc.
**In some Richtek documents the PSM type is called PWM / PSM, DEM, or discontinuous conduction mode, etc.

Technical Document Image Preview

Figure 5. Advantages and disadvantages of the PSM type



Switching Frequency Considerations

The switching frequency is a very important parameter. A higher frequency allows smaller inductors and capacitors and gives better step-load response. But high frequency raises switching loss and widens EMI radiation. It also limits the maximum step-down ratio, since the minimum duty cycle is limited by the minimum on-time and the switching frequency:

Technical Document Image Preview

For example, with tON min = 100nsec, a converter with a minimum duty cycle of 12% cannot step down from 12V to 1.2V; an 800kHz converter with a minimum duty cycle of 8% can step down from 12V to 1.2V.

Very high frequency Buck converters (> 1MHz) are usually used with very low input voltages such as 5V or lower, since switching loss is then lower and the maximum step-down ratio is smaller.

For most 12V applications, 500kHz~800kHz suits best, balancing switching loss and component size.

At high current and high input voltage (> 18V), keep the switching frequency below 500kHz to reduce switching loss and achieve a high step-down ratio.

Frequency effects.png

Figure 6. Effect of a Buck converter's switching frequency on ripple, transient response and efficiency



Selection Criteria for Buck Converter Control Architectures

Richtek's DC/DC portfolio includes Buck converters with many control architectures: current mode (CM), current mode constant on-time (CMCOT), and Richtek's proprietary advanced constant on-time (ACOT). Each has advantages and disadvantages, so when selecting a converter it is best to first understand each architecture.

Current Mode Control

CM.png

Figure 7. CM Buck converter basic circuit diagram and operation waveforms

Current mode converters have an internal clock generator, error amplifier and current sensing. The error signal is compared with the sensed peak current to control the high-side on-time. A new switching cycle starts on the clock signal, so the system must run at a constant switching frequency. Control loop bandwidth is usually about 1/10 of the switching frequency.

Current Mode Buck Converter

Advantages:

  • Stable constant frequency
  • Can be synchronized to an external frequency
  • Mature technology
  • Stable with MLCC

Disadvantages:

  • Slower response to fast load steps
  • Requires error amplifier compensation
  • Requires slope compensation

If the load current is fairly stable, a current mode Buck converter can be used. If the system is noise-sensitive at certain frequencies, current mode is best, since it can be synchronized to an external frequency signal to set the switching frequency precisely. In the LV input range many current mode Buck converters support 100% duty cycle, allowing VIN to be very close to, or equal to VOUT.


Current Mode Constant On-Time (CMCOT) Control

CMCOT.png

Figure 8. CMCOT Buck converter circuit diagram and operation waveforms

A CMCOT Buck converter has no internal clock; the high-side MOSFET always conducts for a preset constant on (ON) time, and the duty cycle is regulated by changing the high-side off (OFF) time. CMCOT converters also have current sensing and an error amplifier, except that the current down-slope is compared with the error amplifier output. Since the system need not wait for the next clock pulse, it responds quickly to a step load. When the output droops, the error amplifier output rises; as soon as it meets the current down-slope, a new on (ON) time starts at once and the converter current rises again.

Current Mode Constant On-Time (CMCOT) Buck Converter

Advantages:

  • Fast response to load steps
  • Low-side current sensing
  • Small minimum on-time, so the duty cycle can be lower
  • Constant average switching frequency
  • Stable with MLCC
  • No slope compensation required

Disadvantages:

  • Requires error amplifier compensation
  • Cannot be synchronized to an external frequency
  • Switching frequency varies during load transients

If the load has moderate transients, a CMCOT Buck converter can be chosen to reduce output voltage deviation during load steps. Compared with current mode Buck converters, CMCOT improves load transient performance by 20%~30% and is less noise-sensitive at low duty cycle. Because the minimum on-time is small, CMCOT Buck converters suit larger step-down ratios, while the switching frequency changes during load transients.


Advanced Constant On-Time (ACOT®) Control

ACOT.png

Figure 9. CMCOT Buck converter circuit diagram and operation waveforms

The ACOT® converter has no error amplifier or current sense circuit; it compares the feedback signal (DC voltage + ripple) directly with an internal reference. When the feedback falls below the reference, a new constant on (ON) time starts and the inductor current rises. If the output has not recovered, after a very short blanking period another on (ON) time starts, until the inductor current reaches the load current and the output recovers to the set value. To pair stably with low-ESR ceramic output capacitors, an internal pulse-shaping regulator (PSR) generates a ripple signal added to the output ripple and DC voltage; the sum is then compared with the internal reference. When this summed voltage is below the reference, the comparator starts the on-time generator (ON Time Generator).

A sudden output voltage drop starts a new on (ON) time at once, and while the output has not recovered the converter can start on (ON) times continuously, so ACOT responds extremely fast to load transients.

A built-in frequency-lock loop slowly adjusts the on-time so the average switching frequency settles at the set value.

Advanced Constant On-Time (ACOT®) Buck Converter

Advantages:

  • Extremely fast response to load step changes
  • No current sensing required
  • Small minimum on-time, so the duty cycle can be lower
  • Constant average switching frequency
  • Stable with MLCC
  • No slope compensation required

Disadvantages:

  • Cannot be synchronized to an external clock
  • Dynamic loads cause a large switching frequency (FSW) variation

If the load has extremely fast transients (as with CPU cores and DDR memory), an ACOT Buck converter is best; its load transient response is 2 to 4 times better and it allows small output capacitors. ACOT converters suit low duty cycle applications especially. Because the minimum on-time is very small, a high-frequency ACOT Buck converter can still serve applications needing a higher step-down ratio. During load transients the ACOT switching frequency also deviates greatly. ACOT has no loop or slope compensation, and with its very fast loop response this makes the circuit simple, flexible and low cost.



Other Selection Criteria for Buck Converters


External Soft-Start

All Richtek Buck converters have soft-start. After startup the duty cycle increases gradually so the output rises smoothly, avoiding inrush current from suddenly charging the output capacitor. Converters with internal soft-start have a fixed soft-start time. If the application needs a very large output capacitor or a specific soft-start time, choose a converter with externally controlled soft-start, whose time is set by an external capacitor.


External Compensation

The error amplifier of a current mode converter needs compensation for stability. Type II compensation components set the bandwidth and phase. Externally compensated converters give more flexibility in setting bandwidth and phase margin, even with different output capacitor types and wide input and output ranges.


Adjustable Frequency

Some converters allow the switching frequency to be set by an external resistor, giving flexibility to pick the optimum frequency. A high frequency reduces ripple and component size and improves transient performance. A low frequency improves efficiency or reduces higher-order harmonics.


External Synchronization Input

Some current mode converters have an external synchronization input that locks the internal clock to an external clock signal, so the switching frequency can be set precisely (avoiding noise in sensitive bands) and several converters can run at the same frequency.


Low Dropout Mode or 100% Duty Cycle Mode

Many LV-series current mode Buck converters have a low dropout mode: when the input falls, they gradually increase the duty cycle, and when the input is below the regulated target they keep the high-side MOSFET on. This suits battery-powered applications especially; when the battery is nearly exhausted it extends operating time.


Power Good Function:

The power good function monitors the output signal of the Buck converter and signals the system that the output voltage is within a specific operating range.
Power good can be used for system initialization, fault protection, or startup sequencing.


Over-Current Protection:

All Richtek Buck converters have over-current protection (OCP). When the inductor current exceeds the OCP value the duty cycle is limited. If the load keeps increasing the output droops. When an overload occurs, the system can respond in several ways:

  • Latched-mode OCP : when an overload occurs and the output falls below the under-voltage protection (UVP) value, the system shuts down and latches. The converter must be re-enabled or power-cycled to restart. This ensures zero power consumption after the overload, but no automatic restart.
  • Hiccup-mode OCP : when an overload occurs and the output falls below the under-voltage protection (UVP) value, the system shuts down and restarts with soft-start. If the overload persists the shutdown / restart cycle repeats, also called hiccup mode. Its advantages are low average overload current and automatic restart once the overload clears.
  • No under-voltage protection (UVP) : when an overload occurs the output voltage drops, but there is no under-voltage protection (UVP). During the overload the system keeps operating at the OCP current. Once the overload clears the output recovers immediately. But operating at the OCP current for a long overload raises temperature.


Considerations for Choosing the IC Package

Richtek Buck converters use many package types: from tiny CSP 1.3x2.1mm, through cost-effective TSOT23-6, to the larger thermally enhanced TSSOP-14.

Technical Document Image Preview

Figure 10: Various IC packages used by Richtek's Buck converters

Several factors decide which IC package suits your application best:

Technical Document Image Preview In some applications IC height and PCB space are tightly constrained (mobile phones, tablet computers and other small portable devices), so a CSP package is best. It requires a multilayer PCB layout and more precise placement and soldering.

 


Technical Document Image Preview

SOP-8 (with exposed thermal pad), DFN2x2 and DFN3x3 are common for Buck converters: they have 6~12 pins, making extra functions easy to add, and the exposed thermal pad gives good thermal performance at lower cost, so they are widely used. A single-layer PCB layout is possible; a multilayer layout is recommended for better thermal and electrical performance.

 


 

Technical Document Image Preview Large packages such as TSSOP-14 or WDFN-14L 4x3 have a bigger thermal pad and can dissipate more power. On the PCB the pad must connect to wider copper traces and to inner layers through vias, to improve cooling.


Technical Document Image Preview

Technical Document Image Preview Among the lowest-cost packages, TSOT23-6 and SOT23-8 are both good choices. Six pins suffice for a basic Buck converter, while eight pins allow extras such as soft-start or PGOOD. These packages have no thermal pad, so most IC heat goes through the pins into the PCB copper. Silicon dies can be assembled in two ways: conventional wire-bonding and flip-chip. Compared with a wire-bonded package, the main advantage of the flip-chip SOT-23-6 is better electrical and thermal performance.


Comparison overview: TSOT-23-6 with conventional wire-bonding versus flip-chip assembly:

Wire-bonded

Flip-chip

Technical Document Image Preview

Technical Document Image Preview

The silicon die is bonded to the middle ground lead; the die's other connections are bonding wires to the leadframe pins, the bonding wire usually being a 25-38µm gold or copper wire.

The front of the silicon die is attached directly to the leadframe through solder bumps, so heat and electricity conduct directly from the die to the leadframe.

Electrical performance differences:

These fine wires add resistance, inductance and stray capacitance at important circuit nodes, degrading the performance of high-frequency switching converters.

The solder bumps are very short, so resistance, inductance and stray capacitance are significantly reduced, and therefore the losses caused by I2R and by switching are reduced accordingly, and the heat generated is also reduced.

Thermal performance differences:

These fine wires are poor thermal conductors, so most of the heat cannot leave through the pins. The main heat path is from the back of the die through the adhesive to the middle ground pin, creating a hot spot there.

All pins act as small heat sinks and cool the device effectively, so more heat passes from the package to the PCB and the die temperature drops.

Technical Document Image Preview To avoid the extra resistance of bonding wires, high output current (≥ 6A) Buck converters often use flip-chip technology. These use UQFN packages with a special leadframe for an optimized die connection, reducing total on-resistance (RDS(ON) ). To optimize package cooling, widen the copper traces to the IC pins in the PCB layout and use thermal vias to the inner layers, improving the PCB's heat dissipation.

 

Technical Document Image Preview