A received lot differs from earlier ones in parameters, or the marking has changed. Why?
Conclusion: judge against the min/typ/max in the datasheet to see whether the part is really out of specification, then check for a PCN.
Symptoms
Measured values differ slightly between lots of the same part number, or the marking and packaging have changed, and the customer is concerned about the incoming material.
Common causes
- Normal process variation between manufacturer lots, still within the datasheet limits
- A change of marking, packaging or assembly site (an item covered by a PCN)
- Parts made in different factories, so the centre of the parameter distribution shifts slightly
Recommended actions
- Judge each parameter against the datasheet min/typ/max rather than comparing directly with the previous lot
- Request the COC, traceability information and outgoing inspection records for that lot
- For marking or packaging changes we proactively pass on the manufacturer's PCN
- If a parameter is genuinely out of specification, follow the RMA and failure-analysis process