The system resets on plug-in or at power-up, or the load switch trips. Why?
Conclusion: the inrush current exceeds the current-limit point and the load switch enters hiccup protection.
Symptoms
At hot-plug or power-up the downstream MCU resets and the load switch repeatedly turns on and off; the oscilloscope shows current spikes at the input.
Common causes
- The inrush current charging the input capacitor exceeds the load switch current limit
- The soft-start time is too short, or there is no soft start at all
- High input line resistance, so the voltage sag during inrush triggers a downstream undervoltage reset
Recommended actions
- Choose a load switch with adjustable soft start or inrush control and extend the start-up ramp
- Increase the input capacitance and reduce the line resistance to limit the transient droop
- Add a TVS diode or an RC snubber to suppress plug-in spikes if necessary