The system resets on plug-in or at power-up, or the load switch trips. Why?

FAQ

The system resets on plug-in or at power-up, or the load switch trips. Why?

Conclusion: the inrush current exceeds the current-limit point and the load switch enters hiccup protection.

Symptoms

At hot-plug or power-up the downstream MCU resets and the load switch repeatedly turns on and off; the oscilloscope shows current spikes at the input.

Common causes

  • The inrush current charging the input capacitor exceeds the load switch current limit
  • The soft-start time is too short, or there is no soft start at all
  • High input line resistance, so the voltage sag during inrush triggers a downstream undervoltage reset
Current I t No soft start: inrush trips the current limit With soft start / current ramp At power-up the large load capacitance looks like a short circuit, OCP trips and the part hiccups

Recommended actions

  1. Choose a load switch with adjustable soft start or inrush control and extend the start-up ramp
  2. Increase the input capacitance and reduce the line resistance to limit the transient droop
  3. Add a TVS diode or an RC snubber to suppress plug-in spikes if necessary