The LDO dropout is insufficient and the output follows the input down. Why?
Conclusion: dropout is specified at the rated current; coping at low current does not mean coping at full load.
Symptoms
When the input voltage approaches the output voltage the output falls below its set value; it is correct at light load and sags as soon as current is drawn.
Common causes
- The input voltage is below the dropout voltage (note that this parameter increases as the load current rises)
- The load current exceeds the rating and the device enters current limit
- The input source has a high internal resistance and its voltage drops under load
Recommended actions
- Check the dropout curve in the datasheet and leave enough input headroom for the maximum load
- Reduce the load, or choose a part with a higher current rating
- Increase the input capacitance and shorten the supply path to reduce the line resistance