The LDO output self-oscillates or does not regulate. Why?
Conclusion: in most cases the capacitance and ESR of the output capacitor fall outside the device's stable region.
Symptoms
A continuous oscillation from tens of kHz to several MHz appears at the output, more pronounced when the load changes; the multimeter reading jumps and the downstream circuit misbehaves.
Common causes
- The output capacitor value or its ESR is outside the stability window required by the datasheet
- No feed-forward capacitor is fitted, so the loop phase margin is insufficient
- Long input and output traces and a dirty ground return let noise couple into the feedback
- The load itself is capacitive (a long cable), which effectively changes the loop
Recommended actions
- Check capacitance and ESR together against the stable operating region curve in the datasheet; capacitance alone is not enough
- Add a 10-100 nF feed-forward capacitor where necessary (bearing in mind its effect on the load transient response)
- Shorten the input and output loops and take the feedback directly at the output capacitor
- For capacitive loads, add a small series resistor at the output, or choose a part that is insensitive to capacitive load