The load-transient droop is large and recovery is slow. Why?

FAQ

The load-transient droop is large and recovery is slow. Why?

Conclusion: transient response is set jointly by the output capacitor, the inductor and the loop bandwidth.

Symptoms

When the load steps (RF transmission, motor start-up), the output voltage undershoots noticeably, the system resets or the ADC samples incorrectly, and recovery takes too long.

Common causes

  • Not enough output capacitance to supply the transient current
  • Inductance too large, so the current slope cannot follow the load change
  • Loop compensation is too slow (low bandwidth), so recovery is sluggish
  • The feedback sense point is too far from the load, so the trace drop is regulated into the loop

Recommended actions

  1. Add output capacitance, or parallel polymer or tantalum capacitors to lower the ESR
  2. Reduce the inductance where ripple allows, to increase the current slope
  3. Adjust the compensation network as described in the datasheet to raise the crossover frequency
  4. Use remote sensing (Kelvin connection) and route the feedback trace away from the switch node