The load-transient droop is large and recovery is slow. Why?
Conclusion: transient response is set jointly by the output capacitor, the inductor and the loop bandwidth.
Symptoms
When the load steps (RF transmission, motor start-up), the output voltage undershoots noticeably, the system resets or the ADC samples incorrectly, and recovery takes too long.
Common causes
- Not enough output capacitance to supply the transient current
- Inductance too large, so the current slope cannot follow the load change
- Loop compensation is too slow (low bandwidth), so recovery is sluggish
- The feedback sense point is too far from the load, so the trace drop is regulated into the loop
Recommended actions
- Add output capacitance, or parallel polymer or tantalum capacitors to lower the ESR
- Reduce the inductance where ripple allows, to increase the current slope
- Adjust the compensation network as described in the datasheet to raise the crossover frequency
- Use remote sensing (Kelvin connection) and route the feedback trace away from the switch node