The part runs very hot at full load and the temperature rise is too high. Why?
Conclusion: calculate the loss distribution first, then decide whether to change the part or change the layout.
Symptoms
After ten-odd minutes at full load the device or the inductor is too hot to touch, efficiency falls below the datasheet curve, and in severe cases thermal protection reduces the load.
Common causes
- Conduction loss (I2 x RDS(on)) plus switching loss exceed what the package can dissipate
- Inductor DCR too high, giving a large DC loss
- The thermal pad has no copper pour and too few vias, so the heat cannot escape
- High ESR in the input and output capacitors, so the ripple current heats them
| Loss item | Calculation | How to improve |
|---|---|---|
| Conduction loss | Iout2 x RDS(on) x D | Low RDS(on) part, more copper area |
| Switching loss | 0.5 x Vin x Iout x (tr+tf) x fsw | Lower the frequency, optimise the gate drive |
| Inductor DC loss | Iout2 x DCR | Low-DCR inductor, stranded wire |
Recommended actions
- Calculate the losses at full-load current and compare them with the datasheet efficiency curve to confirm that the result is within expectation
- Enlarge the thermal pad and add more thermal vias (at least nine 0.3 mm vias are recommended)
- Switch to a lower-DCR inductor, or raise the switching frequency to shrink the inductor
- If necessary derate the design, or move to a part with lower RDS(on)