Efficiency is low at light load and standby current is too high. Why?
Conclusion: first establish whether the cause is the device's operating mode or leakage in the surrounding circuitry.
Symptoms
Full-load efficiency is normal, but below 10% load or at no load the input current is clearly higher than the datasheet value, and battery-powered products lose a noticeable amount of standby time.
Common causes
- The device runs in forced PWM (FCCM) mode and keeps switching in both directions at light load
- The feedback divider resistors are too low in value and draw a continuous leakage current
- Leakage on the EN pin, or an unsuitable external pull-up/pull-down
- Excessive leakage current in the output capacitor (tantalum capacitors in particular, and aged electrolytics)
Recommended actions
- Move to a part that supports PFM / power-saving mode (pulse skipping at light load)
- Raise the feedback divider resistors to the hundreds of kOhm range, balancing noise against accuracy
- Check the EN threshold and leakage, and add a series resistor to limit the current if necessary
- When measuring standby current, disconnect the downstream load and evaluate the supply on its own