The converter fails to start, hiccups or restarts repeatedly at power-up. Why?
Conclusion: in nine cases out of ten the load capacitance looks like a short circuit at start-up, the current limit trips and the part enters hiccup mode.
Symptoms
After power is applied the output does not come up, or it comes up and then collapses in a periodic restart; on the oscilloscope the input current appears as pulses.
Common causes
- A large capacitor at the load (FPGA, bulk storage capacitor) is effectively a short circuit at start-up
- The EN pin is not pulled up correctly, or the pull-up resistor does not match the device threshold
- The input supply sags under load and trips the UVLO (undervoltage lockout)
- The soft-start time is too short, or the soft-start capacitor is too small
Recommended actions
- Check the EN level and the pull-up resistor, and make sure the pin is not left floating
- Choose a part with adjustable soft start and increase the SS capacitor to extend the start-up ramp
- Check the transient droop and line resistance of the input supply, and add input capacitance if necessary
- For heavy loads, power up in stages or set the current-limit point above the load peak current