The converter fails to start, hiccups or restarts repeatedly at power-up. Why?

FAQ

The converter fails to start, hiccups or restarts repeatedly at power-up. Why?

Conclusion: in nine cases out of ten the load capacitance looks like a short circuit at start-up, the current limit trips and the part enters hiccup mode.

Symptoms

After power is applied the output does not come up, or it comes up and then collapses in a periodic restart; on the oscilloscope the input current appears as pulses.

Common causes

  • A large capacitor at the load (FPGA, bulk storage capacitor) is effectively a short circuit at start-up
  • The EN pin is not pulled up correctly, or the pull-up resistor does not match the device threshold
  • The input supply sags under load and trips the UVLO (undervoltage lockout)
  • The soft-start time is too short, or the soft-start capacitor is too small
Current I t No soft start: inrush trips the current limit With soft start / current ramp At power-up the large load capacitance looks like a short circuit, OCP trips and the part hiccups

Recommended actions

  1. Check the EN level and the pull-up resistor, and make sure the pin is not left floating
  2. Choose a part with adjustable soft start and increase the SS capacitor to extend the start-up ramp
  3. Check the transient droop and line resistance of the input supply, and add input capacitance if necessary
  4. For heavy loads, power up in stages or set the current-limit point above the load peak current